Add to Cart
Product Features
Display Elements Indicator
a Switch off audio signal g Temperature control
b Warning-function h Battery indicator
c Non-metal object i Measuring indicator
d Non-magnetic metal j Fine scale
e Magnetic metal k Indication"CENTER"
f Charged wire
Start-up
Inserting/Replacing the battery
Alkali- manganese batteries are recommended for the measuring tool.
Press the latch of battery lid in the direction of the arrow and open the battery lid.Insert the supplied battery and make sure that the polarity is correct.
You should replace the battery when the battery indicator indicates .
If the tooI is not used for a long period of time,the battery must be removed.
Operation
WARNING:
Make sure the sensor area is not moisture before detecting.
lf the tool was used in extreme temperatures or variations in
temperature, allow the tool to adjust to the ambient temperature before switch it on.
Detection model
There are three type detect this product available: multi-functional wall detector model,metal model,charged wire model.Different detection requirements need to choose a different way.Select "metal" model,can reach a maximum depth of detection of metal. Select "Charged wire model "achieve the maximum depth of detection of charged wires.
Product indication lamp(See diagram label product mark number 5) can display the currently selected detection mode.
Technical Data
Multi-functional wall detector MD120 |
Maximum probing depth |
Magnetic metal 120mm |
Non-Magnetic metal 80mm |
Charged wire 11O 230volts(in the pass through) 50mm |
Wood 38mm |
Switch off instrument with inactivity after 5mins |
Operation temperature -10C~+ 509C |
Storage temperature -20C~+70C |
Battery type 1x9 volts 6L .R61 |
Operation time about 5 hours |
Weight conform to EPTA-Procedure 01/2003 270g |
Protection class IP54 |
Care
Keep the measuring tool clean and dry at all times to ensureproper and safe working.
- Do not immerse the tool in water or other fluids.
- Wipe away debris or contamination with a dry,soft cloth.Do notuse cleaning agents or solvents.
- ln order not to affect the measuring function,decalsstickers orname plates,especiall metal ones,may not be attached in thesensor area 13 on the front or back side of the measuring tool.
- Do not remove the contact pads 12 on the back.
- Do not open the instrument by yourself. Store and transport themeasuring tool only in the supplied soft package.
In case of repairs,send in the tool packed in its soft package.
Warranty
Check the measuring tool each time before use. ln case of visible damage or loose components inside themeasuring tool, safe function can no longer be ensured. When
flashes on the display,send the tool in the providedsoft package to the dealer or our company.
The instrument comes with a one-year warranty. This warrantyeffective premise is:according to the company's operatinginstructions for correct operation,processing,ceanin andmaintenance of the tool,and the tool is maintained good technical condition.This means that in the tool can be used inthe company's original components and spare parts. This warranty is provided in the tool during the whole life expectancyof the defective parts of the repaired or replaced free of charge.If the component due to normal wear and in need of repair ofreplacement,is not in the warranty range. All illustrations ,descriptions and technical specificationsmay be subject to change without prior notice.